Landolt C Ring Optotype Test

International standard visual acuity screening under ISO 8596 and DIN 58220.

Launch Interactive Landolt C Ring Optotype Test

What this check evaluates

The Landolt C ring test is the official reference standard for visual acuity adopted by the International Organization for Standardization (ISO 8596) and the International Council of Ophthalmology. It measures minimum separable acuity by asking the observer to identify the position of a small gap in a circle.

Optical principles and visual mechanisms

Unlike alphabet charts where some letters like L and T are easier to identify than letters like B and S, the Landolt ring provides completely uniform legibility across all presentations. The optotype consists of an outer circle with a diameter subtending five minutes of arc, a stroke width of one minute of arc, and a break or gap subtending exactly one minute of arc. The gap appears in one of eight orientations (up, down, left, right, and four diagonal positions). Recognizing the gap requires pure resolving capability at the one-arcminute limit.

Standard testing procedure at home

After calibrating screen dimensions with a standard bank card, measure three meters from your monitor. Cover one eye with your palm, taking care not to press on the eye. When a Landolt ring appears, indicate the direction of the opening using your directional keypad or on-screen controls. Proceed through progressively smaller rings until you reach your threshold.

Clinical standards and passing benchmarks

In decimal notation, standard vision is recorded as 1.0, which corresponds to 20/20 Snellen or 0.0 LogMAR. Resolving a ring with a two-arcminute gap represents decimal 0.5 (20/40 Snellen), the minimum requirement for driving in many international jurisdictions. Research trials and formal clinical evaluations use Landolt C rings or Sloan letters because they eliminate memorization and language bias.

When to schedule an in-person eye exam

If you score below decimal 0.5 (20/40) with your best corrective lenses, schedule an optometric exam. Because Landolt C testing removes cultural and educational factors, a lower score points directly to an uncorrected refractive error or reduced ocular transparency that needs professional diagnosis.

Scoring & Clinical Thresholds

Gap Opening SizeDecimal Acuity (EU / ISO)Snellen Eq.Licensing Relevance
1.0 arcminute (0.87mm @ 3m)1.0020/20 (6/6)Full standard isotropic acuity
1.25 arcminute0.8020/25 (6/7.5)Minimum better-eye standard for German Klasse C/D
1.43 arcminute0.7020/28.6Mandatory Optician Sehtest threshold (FeV Klasse B)
2.0 arcminutes (1.75mm @ 3m)0.5020/40 (6/12)EU medical specialist / US Class C driving baseline

Frequently Asked Questions

Why do German FeV regulations insist on Landolt rings instead of letters?

Landolt C openings appear across vertical, horizontal, and diagonal directions without orthographic recognition clues, eliminating memorization and letter familiarity bias.

How many rings per row must be named accurately?

Under DIN EN ISO 8596 screening protocols, correctly identifying at least 3 of 5 gap orientations passes a visual acuity step.

Practice Screener Notice

This browser-based check is an educational self-screening and rehearsal tool. It cannot replace a comprehensive medical examination, dilation, or intraocular pressure measurement by an optometrist or ophthalmologist. If you experience visual pain, floaters, flashes, or persistent blur, see an eye care professional.